Es-1, On off, Replacing the wiring within the frame – CatEye EC-3600 User Manual

Page 26

Advertising
background image

Cateye Ergociser Series 1000 Service Manual
24

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

Cable Holders

ON

OFF

ON

OFF

ES-1

ES-1

Inlet Metal Base

Fig. 1

[A] Removing the Wiring Parts

1. Remove the frame cover. (See the Sections D-1 & D-2

"Removing the Frame Covers.")

2. Loosen the two screws on the inlet metal base to remove

them. (Fig. 1)

3. With the stopper being held with fingers, pull the CN-4

connector off the power supply board. (Fig. 2)

4. Cut the cable holder with a nipper. (Fig. 3)

[B] Mounting the Brand New Wiring Parts

1. Mount the brand new inlet metal base to the frame with two

screws.

2. Pass the wiring cable from beneath the DC jack of the power

supply board along with the square pipe (21mm x 21mm) to

the left direction, and then pass it through the back of the inlet

metal base along with the square pipe toward the switch.

3. Connect the CN-4 connector to the power supply board.

4. Refer to the Section (2) "Checking the Wiring within the

Frame" of T-1 "No Display on the Control Unit after Power ON"

(1) , measure the voltage across the electrolytic capacitor C-1

to check that it is in the correct range of 14V and 19V.

5. Use the cable holder to fix the CDC sensor cable together with

the solenoid coil cable. (Fig. 3)

6. Provisionally connect the control unit, and check the unit works

fine after turning on the power. Then, completely assemble

the frame cover.

Screws

ON

OFF

Replacing the Wiring within the Frame

EC-1200 & EC-1600

EC-3600 & EC-3700

Inlet Metal Base

Power Supply Board

Power Supply
Board

Inlet Metal Base (for Upright Type)

DC Jack

Inlet Metal Base (for Recumbent Type)

Screws

DC Jack

Fig. 3

Fig. 2

Power Supply Board

Hold the stopper.

Replacing the Wiring within the Frame

Advertising