Check Method of Causes

Repair Method

Explanation Figures

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

Cateye Ergociser Series 1000 Service Manual

20

T-7-2

T-7-2

Unusual Noise (Periodical)

[2] Noise is Periodical.

1. Noise occurs around once per rotation of the pedal.

The pedal installation may not be perfect. (Fig. 1)

2. Sliding noise occurs around 17 times per rotation of the pedal.

Remove the frame cover, and check the inside of frame. (See the

Sections D-1 & D-2 "Removing the Frame Covers.")

The copper disc plate of the workload unit may touch the

solenoid coil. (Figs. 2 & 3)

Use a No.15 wrench and securely fasten the pedal to

the crank. (both sides)

See the Section ES-4 "Correcting the Position of

Solenoid Coil," and correct the position of the copper

disc plate.

[If the plate is warped and the position of solenoid coil

cannot be corrected, replace the workload unit. (See

the Sections MS-1 & MS-2 "Replacing the Workload

Unit.")]

Fig. 1

No.15 Wrench

Crank

Pedal

Fig. 2

Solenoid Coil

Fig. 3

Core Slit

Copper Disc Plate

Core

Correct Position

Solenoid Coil

Fig. 4

Core Slit

Copper Disc Plate

Core

Copper disc plate is in contact with the core.

Solenoid Coil