Cateye Ergociser Series 1000 Service Manual
46

EC-1200 EC-1600 EC-3600 EC-3700

Applicable Models:

MS-9

MS-9

Replacing the BB Set

REMOVAL

1. Remove the frame cover, by referring to the Sections D-1 & D-

2 "Removing the Frame Covers."

2. Remove the gear crank/crank from the crank shaft(BB axle),

by referring to the Section MS-8 "Replacing the Crank Set."

3. Remove the BB cup locking with a hanger rotating jig. (Fig. 1)

4. Remove the BB adjusting cup, by using a pin face wrench.

(Fig. 2)

5. Remove the crank shaft(BB axle).

6. Remove the BB fixing cup, by using the hanger rotating jig.

(Fig. 3) The CDC sensor metal base will be removed at the

same time.

ASSEMBLING

1. Check if no retainer remains within the hanger, and mount the

BB fixing cup. Be sure that the CDC sensor metal base should

first be mounted before mounting the BB fixing cup.

2. Assemble the crank shaft(BB axle), retainer, BB fixing cup, BB

adjusting cup, BB cup locking and CDC sensor metal base as

depicted in Fig. 4.

3. Mount the gear crank/crank, by referring to Mounting Items (1)

thru (5), Section-MS-8 "Replacing the Crank Set." Also, adjust

the tension of the chain.

4. Adjust the following:

1. Align the line on the CDC sensor with the center of the line

on the magnet. (Fig. 5)

2. Adjust the clearance between the CDC sensor surface and

the magnet surface to be approx. 2mm. (Fig. 6)

* When the specified clearance has not been established,

bend the metal base to have the clearance.

5. Provisionally turn on the power, and check if the pedal

cadence is displayed on the control unit.

6. Assemble the frame cover, by referring to the Sections D-1 &

D-2 "Removing the Frame Covers."

Replacing the BB Set

BB Set

EC-1200 & EC-1600

BB Set

EC-3600 & EC-3700

Fig. 1

Hanger Rotating
Jig

Fig. 2

BB adjusting cup

Pin Face Wrench

Fig. 3

Hanger Rotating
Jig

CDC Sensor Metal
Base

Fig. 4

CDC Sensor Metal Base

Retainer

Retainer

Hanger Pipe

Fig. 5

CDC Magnet

Line

CDC Sensor

Fig. 6

CDC
Sensor

CDC
Magnet

Line

Center

Center

Approx. 2mm Clearance between CDC
Sensor and Magnet

Crank Shaft
(BB axle)

BB cup locking

BB fixing cup

BB cup locking

BB adjusting cup

BB fixing cup

Advertising
This manual is related to the following products: