Replacing the Idler Set

1. Remove the frame cover by referring to the Sections D-1 & D-

2 "Removing the Frame Covers."

2. Remove the idler spring from the pawl of the idler metal base.

(Fig. 1)

3. Loosen the idler mounting bolts, and detach the idler set. (Fig.

2)

4. Mount a brandnew idler set by using an idler mounting bolt.

5. Hang the idler spring on the pawl of the idler to give tension to

the belt.

Idler Set

EC-1200 & EC-1600

Idler Set

EC-3600 & EC-3700

Fig. 1

Idler

Idler Spring

Fig. 2

Idler

Idler Fixing
Bolt