Interlogix NX-4V2 User Manual User Manual

Page 19

Advertising
background image

NX-4V2 LED Keypad User Manual

15

Table 5: Service light problems

Light

Problem

1

SYSTEM FAULT - Press the [1] key. The zone light(s) that is illuminated corresponds to
the system fault(s) below:

1 Over Current Fault

2 Siren Trouble

3 Box Tamper

4 Expander Power

5 Expander Low Battery

6 Expander Box Tamper

7 Expander Trouble

8 Ground Fault

Note: Faults 1 & 2 are global in nature and will affect all partitions of a multi -
partition system
. Press the [#] key to return to the 1 of 8 service lights.

2

ZONE TAMPER - Press the [2] key and the zone light(s) will illuminate showing the
zone(s) that are tampered. Press the [#] key to return to the 1 of 8 service lights.

3

ZONE LOW BATTERY - Press the [3] key. The zone light(s) will illuminate showing
which zone(s) has a low battery. This only applies to wireless zones. Press the [ #] key to
return to the 1 of 8 service lights.

4

ZONE LOSS OF SUPERVISION - Press the [4] key and the zone light(s) will illuminate
showing which zone(s) has loss of supervision. This only applies to wireless zones.
Press [#] key to return to the 1 of 8 service lights.

5

ZONE TROUBLE - Press the [5] key and the zone light(s) will illuminate showing which
zone(s) has a trouble condition. Press the [#] key to return to the 1 of 8 service lights.

6

TELEPHONE FAULT - Press the [6] key. The zone light(s) that is illuminated
corresponds to the system fault(s) below:

6 Line Trouble / Line Cut - This light will illuminate when there is telephone line trouble
or the telephone line has been cut. The service light will remain lit until the telephone
trouble clears and a user code is entered.

7 Auxiliary Comm Device Fail - Radio backup has failed.

7

FAILURE TO COMMUNICATE - This light will illuminate when there is a failure to
communicate between your system and the central station.

8

LOSS OF SYSTEM TIME - This light will illuminate when there has been a loss of power
and your system clock needs to be reset.

Exit

Press the [#] key to exit the Service Light mode.