11

LIGHT

AUTHORITY LEVELS IF LIGHT 8 IS OFF

1

Reserved (Note: Do not change if on.)

2

Arm Only

3

Arm Only After Clos ing Time

4

Master Arm/Disarm (can program other codes)

5

Arm/Disarm

6

Bypass Zones

7

Open / Close Reporting

8

If this light is on, this code is programmed as a
function code. Do not change! Press [#] - [#] to
exit.


Step 6

Press the [

] key. The ready light will flash. This moves you to the

partition enable. (The user has access in partitions that are
illuminated.)


Step 7

The illuminated numbers indicate each partition where the user
has access. To change any of the partitions where the user has
access, press numbers corresponding to areas where you want to
give the user access or deny access. (Example: If zone light #2 is
lit, then the user is assigned access to partition #2. By pressing the
[2] key, the light will go off, denying access to partition #2. Refer to
chart shown below.

LIGHT

PARTITIONS ASSIGNED

1

Partition 1

2

Partition 2


Step 8

When the partitions are assigned, press the [

] key. This returns

you to Step 3 previously mentioned. At this point you may enter
another user number to assign authority level. Repeat Steps 4 - 8
until you have assigned authority levels to all user numbers.


Step 9

Press the [#] key to exit the Assigning Authority Level Program.