Interlogix TVE Series User Manual

Page 30

Advertising
background image

26

TVE-400/800-1600 H.264 IP Video Encoder User Manual

Under

Alarm Linking

check one of more of the desired the response

methods:

- Audible warning: Trigger an audible beep when an alarm is detected

- Notify surveillance center: Send a notification or alarm signal to remote

alarm host when an event occurs. The alarm host refers to the computer
installed with remote client software

- Send e-mail: Send an e-mail with alarm information to a user or users

when an event occurs.

Under

Trigger Alarm Output

select the channel to trigger an external alarm

output when a motion detection event occurs

. See “To set up an alarm

output” below on how to set up an external alarm output.

Select the channel to trigger recording when a motion detection event occurs.

7. Click

Save

to save settings

.

To configure an alarm output:

1. Click

Device

Configuration

>

Alarm Settings

>

Alarm Output.

The Alarm

Output window appears.

2. Select an alarm output.

3. Select a time out option.

The time out setting lets you define how long a signal remains active after the
alarm has ended. Select a time out option: 5, 10, and 30 seconds, 1, 2, 5, and
10 minutes, and Manual stop. If “Manual stop” is selected, the alarm output
will stop only when the alarm input stops.