Connections 3, Connections – Interlogix TVE Series User Manual

Page 7

Advertising
background image

TVE-400/800-1600 H.264 IP Video Encoder User Manual

3

Item

Name

Description

5.

LAN

Connect the 10M/100Mbps self-adaptive UTP Ethernet port to a
network.

6.

Video In

Connect up to 16 analog cameras (depending on model) to the
BNC connectors.

7.

Audio In

Connect an audio input to the RCA connector.

8.

Audio Out

Connect an audio output the RCA connector.

9.

GND

Connect to ground.

Connections

See Figure 2 on page 2 for information on connecting the power, camera, audio
and network cables.

Alarm connections

The TVE encoder supports the open/close relay input as the alarm input mode.
When the alarm input signal not in open/close relay signal mode, please follow
the connections shown below:

Figure 3: Alarm input connections

Alarm input connections for Emerson alarm:

100

ALM(-)

IN(n)

G

ALM(+)

TVE

Relay input

V-output

Emerson alarm

10 V regulator

10 V regulator

14N34

optocoupler

Alarm input connections for normal alarm:

JQC-3FG
24 V relay

ALM(-)

ALM(+)

IN(n)

G

TVE

Relay input

V-output

Alarm

Advertising