Wiring the keypad

The keypad uses RS-485 simplex wiring. The signal is transferred by a single
twisted pair line. A shielded STP CAT5 network cable is recommended. Ground
one end of the cable, either the first or last device on the RS-485 line.

The maximum number of devices that can be installed in one bus is 255, with a
maximum cable length of 1200 m. The cable length can be expanded using a
signal distributor.

Both the first and the last device in series should be terminated with 120 Ohm
resistance to minimize line reflections. See Figure 3 below.

Figure 3: RS-485 bus serial wiring (KTD-405 keypad shown)

1. Keypad
2. I/O box

3. See section “RS-485 ports” on page 12

Use an RS-485 signal distributor for a star wiring configuration. See Figure 4 on
page 11.