Rs-485 ports – Interlogix DVR 41 User Manual User Manual

Page 18

Advertising
background image

1BChapter 2: Installation

12

TruVision DVR 41 User Manual

Figure 5: Expanding the system with an RS-485 signal distributor

1. Keypad
2. I/O box

3. RS-485 distributor
4. See section “RS-485 ports” below

Caution

:

Most signal distributors are unidirectional. This means that the signal

only flows from the input towards the outputs. Consequently it is not possible to
connect several keypads.

See section “RS-485 ports” below to configure the RS-485 port communication
settings.

RS-485 ports

There are two RS-485 ports on the back panel of the DVR. See Figure 6 on page
13 for the serial pin outs.

Dome RS-485:

A and B: Connect pan, tilt, zoom control of PTZ dome cameras. A = +, B = -

C and D: Not used

G: Ground of dome camera

G: Ground of keypad

Keyb: Connect the keypad.