KLVTB039

ROW-END ERROR: TABLE(table) READ(mmm) EXPECTED(nnn)

Explanation: While processing a tables request, the CT/Engine tables manager
detected invalid synchronization information in the tables database for table. An
internal end-of-row marker is missing. mmm is the number of rows successfully
processed; nnn is the number of rows that were expected.
System Action: The tables manager will attempt to load a previous copy of the
table, if one exists (message KLVTB035), or will use the partially loaded table
(message KLVTB034).
User Response: None.
Message Type:

LOG.

KLVTB040

KLVTBMGR LOGIC ERROR

Explanation: The CT/Engine tables manager detected an invalid condition
while performing a request.
System Action: The request is terminated with a U0200 abend, sending a
dump to the RKLVSNAP file and/or the system’s dump datasets.
User Response: Retain the CT/Engine run sheets, dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

REPLY.

KLVTB041

KLVTBMGR INVALID TABLE DELETE POINTER

Explanation: The CT/Engine tables manager detected an invalid condition
while performing a request.
System Action: The request is terminated with a U0200 abend, sending a
dump to the RKLVSNAP file and/or the system’s dump datasets.
User Response: Retain the CT/Engine run sheets, dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

REPLY.

KLVTB042

FREE $TUB INTEGRITY CHECK FAILED

Explanation: The CT/Engine tables manager detected a problem with an
internal control block while performing a request.
System Action: The request is terminated with a U0200 abend, sending a
dump to the RKLVSNAP file and/or the system’s dump datasets.
User Response: Retain the CT/Engine run sheets, dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

REPLY.

KLVTB043

UNSUPPORTED/INVALID $DMTB REQUEST RECEIVED

Explanation: The CT/Engine tables manager was passed an invalid request.
System Action: The request is terminated with a U0200 abend, sending a
dump to the RKLVSNAP file and/or the system’s dump datasets.
User Response: Retain the CT/Engine run sheets, dump files, this message,
and the MVS system log, then contact Candle Customer Support.
Message Type:

REPLY.