Candle KLVHSKONCT GC32-9172-00 User Manual

Page 64

Advertising
background image

64

Candle Products Messages Manual (KLVHS–KONCT)

KLVOP975

COMMAND ERROR, INTERNAL: value IS INVALID

Explanation: A GTF command with an invalid value for the INTERNAL
operand has been entered.
System Action: The command is rejected.
User Response: Valid values for the INTERNAL operand are YES or NO.
Message Type:

ERROR.

KLVPA001

SYNAD ERROR: synadmsg

Explanation: A physical error occurred while reading a partitioned dataset. The
operating system provides synadmsg, which is documented in IBM’s Macro
Instructions for Data Sets

. The text of synadmsg includes the jobname, stepname,

unit address, device type, ddname, operation, error description, absolute track
address, and access method. Message KLVPA002 is issued to provide additional
diagnostic information. If the data set is a PDS/E, message KLVPA007 may follow
with additional operating system information.
System Action: The library is closed then reopened, and the operation is
retried.
User Response: Examine the text of synadmsg and KLVPA002 to determine
the reason for the error. If the error description in synadmsg is OUT OF
EXTENT, compress the library after the CT/Engine address space has been
terminated and is not running.
Message Type:

INFO.

KLVPA002

SYNAD ERROR SENSE AND STATUS BYTES: xxxxyyyy

Explanation: A physical error has occurred while reading a partitioned dataset.
xxxx

contains sense bytes 1 and 2, and yyyy contains status bytes 1 and 2 as

documented in IBM’s Using Data Sets. Message KLVPA001 was issued prior to
this to provide additional diagnostic information.
System Action: The library is closed, reopened, and the operation is retried.
User Response: Review message KLVPA001 and examine the sense and status
bytes to determine the cause of the error.
Message Type:

INFO.

KLVPA003

LIBRARY ddname REFRESHED, SYNAD EXIT DRIVEN

Explanation: A physical error has occurred while reading the library referenced
by ddname. The library has been closed and reopened in an attempt to recover
from the failure. Messages KLVPA001 and KLVPA002 have been issued to
provide diagnostic information regarding the error.
System Action: None.
User Response: None.
Message Type:

INFO.

Advertising