Candle Products Messages Manual (KLVHS–KONCT)

KN3PN020

OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - APF
AUTHORIZATION FAILED

Explanation: OMEGAMON II for VTAM is not running with APF-authorization.
System Action: OMEGAMON II for VTAM fails to initialize and shuts down.
User Response: Verify that each library in the STEPLIB concatenation for
OMEGAMON II for VTAM is APF-authorized.
Message Type:

Probable user error.

KN3PN021

OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - INVALID
VTAM LEVEL DETECTED

Explanation: OMEGAMON II for VTAM was started under an unsupported
release of VTAM.
System Action: OMEGAMON II for VTAM fails to initialize and shuts down.
User Response: Contact Candle Support Services to order the proper
maintenance for your VTAM release.
Message Type:

Probable user error.

KN3PN022

OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - UNABLE
TO OPEN CNM ACB. ACBERFLG(
acberr_name)

Explanation: OMEGAMON II for VTAM was unable to open the ACB used for
communication network management (CNM) communication with VTAM.
acberr_name

contains the contents of the ACBERFLG field of the ACB, in

hexadecimal.
System Action: OMEGAMON II for VTAM fails to initialize and shuts down.
User Response: Look up the meaning of acberr_name in the IBM publication
VTAM Programming

. The following are some common values for acberr_name:

Correct the problem as indicated, and contact Candle Support Services.
Message Type:

Probable user error.

KN3PN023

OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - UNABLE
TO ACTIVATE PMI EXIT. ERROR(
pmi_error)

Explanation: OMEGAMON II for VTAM was unable to activate the
Performance Monitor Interface exit in a VTAM 4.3 environment. pmi_error
contains the error code as indicated by VTAM in the IST985I message.
System Action: OMEGAMON II for VTAM fails to initialize and shuts down.
User Response: Look up the meaning of pmi_error in the IBM publication
VTAM Message and Codes

. A common value for pmi_error is

For other values of pmi_error, contact Candle Support Services.
Message Type:

Probable user error.

58

APPLID is already opened by another ACB.

5A

APPLID is not defined to VTAM. Verify that the major node
containing the APPL statement referenced in
RKANPAR(KN3CNMAP) has been varied active to VTAM.

20

Unable to load the exit module. Verify that the OMEGAMON II for
VTAM load library is part of the VTAMLIB concatenation within the
VTAM start-up JCL.