Candle KLVHSKONCT GC32-9172-00 User Manual

Page 80

Advertising
background image

80

Candle Products Messages Manual (KLVHS–KONCT)

System Action: None.
User Response: None.
Message Type:

REPLY.

KLVSD005

LIMIT(stolim) SLOPE(sl) SIZES(range) TOTAL(tot)

Explanation: This message appears in response to the CT/Engine STORAGE
operator command and displays storage parameters about primary or extended.
It follows KLVSD001 and KLVSD002, or KLVSD004 if DETAIL was requested.

System Action: None.
User Response: None.
Message Type:

REPLY.

KLVSD006

FREE(free) CARVED(carved) OVERHEAD(ovhead)

Explanation: This message appears in response to the CT/Engine STORAGE
operator command and specifies additional information about primary and
extended storage. It follows KLVSD005.

System Action: None.
User Response: None.
Message Type:

REPLY.

stolim

Specifies (in bytes) the size of the largest block that can be
allocated.

sl

A Candle-internal parameter.

range

Specifies the number of storage areas.

tot

Specifies (in kilobytes) the total amount of storage available to
end-user applications and CT/Engine functions. Storage not
included in this total is storage obtained during CT/Engine
initialization for the following:

®

resident load modules

®

internal trace table

®

Logical Resource Table

®

log buffers

This storage is excluded from the tot field of the display because
once allocated it remains allocated for the life of the address space.

free

Specifies (in kilobytes) the amount of storage available.

carved

Specifies (in kilobytes) the amount of storage allocated for use in
fulfilling storage requests.

ovhead

Specifies (in bytes) the amount of storage used for storage control.