Candle KLVHSKONCT GC32-9172-00 User Manual

Page 475

Advertising
background image

KOGCM001–KONCT303

475

KOGVL05S

UNABLE TO DETERMINE SLU APPLID

Explanation: An attempt to determine the SLU APPLID of the VU Client failed.
System Action: VU Server logon fails and the LU0 session with the VU Client
is terminated.
User Response: Call Candle Customer Support if this message occurs during
normal operation of the CT/DS address space.

KOGVL06S

UNABLE TO LOCATE VU SERVER IPC QUEUE

Explanation: An attempt to locate the VU Server Inter-process communication
queue has failed. This message normally occurs if a logon is attempted while the
VU Server is terminating or while the CT/DS address space is terminated.
System Action: VU Server logon fails and the LU0 session with the VU Client
is terminated.
User Response: Call Candle Customer Support if this message occurs during
normal operation of the CT/DS address space.

KOGVL07S

IPC QUEUE ERROR=rc

Explanation: An attempt to transmit data to the VU Server Inter-process
communication queue has failed. The rc value is the return code issued by the
IPC service routine and can be used to determine the cause of the IPC error.
This message normally occurs if a logon is attempted while the VU Server is
terminating or while the CT/DS address space is terminated.
System Action: VU Server logon fails, and the LU0 session with the VU Client
is terminated.
User Response: Call Candle Customer Support if this message occurs during
normal operation of the CT/DS address space.

KOGVL08E

UNABLE TO INITIALIZE rname

Explanation: An attempt to initialize a logical resource has failed. The rname
value indicates the name of the resource that could not be initialized.
This message normally occurs if a VU API service request is attempted while the
VU Server is terminating or while the CT/DS address space is terminated.
System Action: VU API service request fails, and an error code is returned to
the VU Client.
User Response: Call Candle Customer Support if this message occurs during
normal operation of the CT/DS address space.

KOGVL09E

UNABLE TO ALLOCATE MEMORY FOR rname

Explanation: An attempt to allocate memory for a logical resource has failed.
The rname value indicates the name of the resource that could not be allocated.
This message can occur if a VU API service request is attempted when the CT/DS
address space is experiencing a virtual storage shortage.
System Action: VU API service request fails and an error code is returned to
the VU Client.
User Response: Review CT/DS startup parameters controlling the allocation of
primary and extended virtual storage and verify that sufficient storage is available.
Call Candle Customer Support if this message occurs during normal operation of
the CT/DS address space.

Advertising