KMQMI207W

SAMPINT IS INCREASED TO seconds SECONDS BECAUSE VALUE
SPECIFIED IN CONFIGURATION FILE (seconds) IS TOO SMALL.

Explanation: The SAMPINT specified in the MQSeries Monitoring Agent
configuration file was not large enough to collect all MQSeries data samples.
System Action: SAMPINT is increased and processing continues normally.
User Response: Consider increasing the SAMPINT value in the MQSeries
Monitoring Agent configuration file.

KMQMI208I

ERROR LOG MONITORING FEATURE IS TURNED OFF

Explanation: The Error Log monitoring feature has been disabled by specifying
ERRLOGCYCLE(0) on either the SET MANAGER or SET GROUP monitoring
option. See the OMEGAMON XE for WebSphere MQ Monitoring User’s Guide
for descriptions of monitoring options.
System Action: Processing continues with Error Log monitoring disabled.
User Response: None.

KMQMI209E

SITUATION situationname FOR MESSAGE STATISTICS ATTRIBUTE
GROUP MUST SPECIFY SINGLE QUEUE NAME.

Explanation: The specified situation must specify the Queue_Name attribute
with an equal operator. A separate situation must be written for each individual
queue name. The reason for this requirement is because of the overhead of
collecting this data. This information should only be collected for specific queues
that need to be closely monitored.
System Action: No rows are returned for the requested situation.
User Response: Modify the situation to specify a specific queue name for the
Queue_Name attribute.

KMQMI210E

COLLECTION OF MESSAGE STATISTICS FAILED. QUEUE=queuename,
USERID=
userid, RC=reasoncode

Explanation: Collection of message statistics for the specified queue was
requested by either a situation or an ad-hoc report request. The attempt to browse
messages on the queue failed with the specified return code. Return code values
below 9000 are values returned from WebSphere for MQSeries. Additional
information about these return codes may be obtained by referring to IBM
documentation. Some possible values are:

2001

Alias Base Q Type Error

2063

Security_Error

2004

Buffer Error

2069

Signal_Outstanding

2005

Buffer Length Error

2070

Signal_Request_Accepted

2009

Connection Broken

2071

Storage_Not_Available

2010

Data Length Error

2079

Truncated_Msg_Accepted

2011

Dynamic_Q_Name_Error

2080

Truncated_Msg_Failed

2016

Get_Inhibited

2082

Unknown_Alias_Base_Q

2017

Handle_Not_Available

2085

Unknown_Object_Name

2018

Hconn_Error

2086

Unknown_Object_Q_Mgr