Telephone Entry

Quick S

tart Guide

5.3

Program Commands

Once in programming mode, you can change any of the EntraGuard Bronze’s programmable
commands. The general process for changing an existing command value is as follows:

1. Enter the two-digit programming command code for the command you wish to change.
2. If applicable, enter the new value (some commands simply enable or disable a feature and do

not have an associated value).

-

If an entry error has been made, press

and start again from Step 1.

3. Press

to lock in the change.

-

If the entry is valid, the unit emits a short, high-pitched tone to indicate the change has been
accepted.

-

If the entry is invalid, the unit emits a short, high-pitched tone followed by a low-pitched
tone to indicate the change has been rejected.

4. Return to Step 1 to enter another program command change, or to exit programming mode,

either press

or hang up (if using the residence telephone).

Programming examples are provided with each of the commands described below.

5.3.1

Add Entry Code

An Entry Code is a three-digit number entered at the EntraGuard Bronze unit which allows the user
to activate a gate relay (see “Gate Operation From The EntraGuard Bronze Unit” on page 11). You
can have up to 50 entry codes. The EntraGuard Bronze comes with four pre-programmed Entry
Codes, see the EntraGuard Bronze Residence Guide (P/N 01911-003). The factory default is “123.”
Perform the following to add an entry code.

1. Press .

2. Enter the desired three-digit entry code –

.

3. Press

to lock in the new entry code. The unit emits a short, high-pitched tone to indicate the

new entry code has been accepted. The unit emits a short, high-pitched tone followed by a low-
pitched tone if the entry code has been rejected.

EXAMPLE: Enter the following to set an Entry Code of “159.”

4. You can now enter another program command or press

to exit programming mode.