Telephone Entry

Quick S

tart Guide

EXAMPLE: Enter the following to set the maximum number of rings to “10.”

4. You can now enter another program command or press

to exit programming mode.

5.3.8

Set Gate 1 Relay Access Code

The Gate 1 Relay Access Code is a single-digit number that, when entered at the residence
telephone, activates gate relay 1 allowing access. Perform the following to set the gate 1 relay
access code.

1. Press .

2. Enter the desired relay 1 activation code –

(default code is “9”).

3. Press

to lock in the new gate 1 relay access code. The unit emits a short, high-pitched tone

to indicate the gate 1 relay access code has been accepted. The unit emits a short, high-pitched
tone followed by a low-pitched tone if the gate 1 relay access code has been rejected.

EXAMPLE: Enter the following to set a Relay 1 Activation Code of “5.”

4. You can now enter another program command or press

to exit programming mode.

5.3.9

Set Gate 1 Relay Timeout

The Gate 1 Relay Timeout sets the time, in seconds, that the gate 1 relay is activated. The timeout
value range is from 1 to 65 seconds; if you enter 0, the relay will never open. Perform the following
to set the gate 1 relay timeout value.

1. Press .

2. Enter the desired gate 1 relay timeout value –

(default value is 5 seconds). If the

entered timeout value is out of range an error tone sounds and the input is ignored.

3. Press

to lock in the new gate 1 relay timeout value. The unit emits a short, high-pitched

tone to indicate the gate 1 relay timeout value has been accepted. The unit emits a short, high-
pitched tone followed by a low-pitched tone if the gate 1 relay timeout value has been rejected.