2.2.1

Earth Ground

For safety and for EMI noise reduction reasons, the EntraGuard Bronze’s enclosure must be earth
grounded. Using a ground wire, connect the unit’s enclosure to a known earth ground (such as a
ground rod or a conductive cold water pipe), observing all applicable codes.

2.2.2

Power

The EntraGuard Bronze uses a 20 VA plug-in transformer which must be plugged into an
unswitched (always ON), standard 120 VAC wall outlet. For best operating conditions:

The outlet should be free from any other loads (preventing power fluctuations from affecting the
unit).

Locate the outlet/transformer as close as possible to the unit.

Ensure the transformer will not be accidentally unplugged from the outlet.

If the transformer cable length is not sufficient to reach from outlet to unit, additional cable can be
added. To ensure proper voltage and current at the unit, Table 1 lists the wire gauge to use based on
run distance.

Table 1: Recommended Wire Gauge per Run

Distance

Wire Length in Feet Minimum Wire Gauge

0 to 200

18

201 to 500

16

501 to 1000

14

1001 to 2000

12