LAARS NeoTherm NTV (Sizes 399-850 MBTU/h) - Service Manual User Manual

Page 55

Advertising
background image

45

Service Manual - NeoTherm 500

11. The location where you removed the Venturi is the

air intake for the blower. To clean the blower, blow

compressed air through the intake and spin the

impeller.

12. To reassemble, reverse the procedure listed above.
13. Replace the gasket on the inner surface of the cover

for the heat exchanger. The gasket should sit in its

slot as shown in Fig. B23-9.

14. When attaching the front cover of the heat exchang-

er, tighten the nuts in a cross-pattern. See Fig. B23-

10. (If you tighten all of the nuts on one side first,

this might bend or distort the cover.)

15. Check for gas leaks using a leak detection solution.
16. Finish reassembling the unit and turn on the power

and gas. Check for proper venting and combustion

air. Fire the boiler and check the combustion using a

combustion analyzer.

Fig. B23-9 - Gasket in correct position

Fig. B23-10 - Tightening sequence for nuts on front

cover

2

3

4

5

6

1

B23

cont.

Removing and Replacing the Blower (continued)

Advertising