SECTION 1.

General Information

USING THIS MANUAL – Because the

Pennant Boilers and Pennant Water Heaters are

identical appliances, with the exception of materials

of manufacture, labels and ultimate use application,

this manual provides information for the proper

installation, operation and maintenance of both

products. Where differences exist between the

application of the appliances and their operation,

the sections pertinent to only one appliance or the

other will be so identified.

In the Commonwealth of Massachusetts, this

appliance must be installed by a licensed plumber or

gas fitter.

WARNING

The Pennant hydronic, boiler or water heater

must

be installed in accordance with the procedures

detailed in this manual, or the Laars Heating

Systems warranty may be voided. The installation

must conform to the requirements of the local

jurisdiction having authority, and, in the United

States, to the latest edition of the National Fuel

Gas Code, ANSI Z223.1/NFPA54. In Canada, the

installation must conform to the latest edition of

the Natural Gas and Propane Installation Code,

CSA B149.1 and/or local codes. Where required by

the authority having jurisdiction, the installation of

Pennant appliances must conform to the Standard

for Controls and Safety Devices for Automatically

Fired Boilers, ANSI/ASME CSD-1. Any

modifications to the boiler, its gas controls, or wiring

may void the warranty. If field conditions require

modifications, consult the factory representative

before initiating such modifications.

1.1 Introduction

This manual provides information necessary for

the installation, operation, and maintenance of Laars

Heating Systems Pennant copper tube appliances.

Read it carefully before installation.

All application and installation procedures

should be reviewed completely before proceeding with

the installation. Consult the Laars Heating Systems

factory, or local factory representative, with any issues

or questions regarding this equipment. Experience

has shown that most operating issues are caused by

improper installation.

The Pennant appliance is protected against over

pressurization. A pressure relief valve is fitted to all

appliances. It is installed on the outlet header, at the

water outlet of the appliance.

IMPORTANT: The inlet gas pressure to the appliance

must not exceed 13" w.c. (3.2kPa).

All installations must be made in accordance with:

1) In the U.S., the " National Fuel Gas

Code"ANSI Z223.1/NFPA54, Latest Edition and all

applicable local codes as required by the Authorities

Having Jurisdiction (AHJ), or

2) In Canada, the "Natural Gas and Propane

Installation Code", CSA B149.1, latest edition and all

applicable local codes as required by the AHJ.
All electrical wiring is to be done in accordance with:

1). In the U.S., the "National Electrical Code"

(NEC), ANSI/NFPA 70, latest Edition and all

applicable local codes as required by the AHJ, or

2). In Canada, the “Canadian Electrical Code

- Part 1”, CSA STD. C22.1 and all applicable local

codes as required by the AHJ.

This appliance must be electrically grounded in

accordance with the applicable codes and standards

referenced above.

Model Nomenclature

1

2

3 4 5

6

7

8 9 10 11 12 13 14

15 16

P N C

A

C

2

SERIES

P

N

C

USAGE

H - HYDRONIC
V - VOLUME WATER

SIZE

MBTU/h

0 5 0 0

0 7 5 0
1 0 0 0

1 2 5 0

1 5 0 0

1 7 5 0

2 0 0 0

FUEL

N - NATURAL
P - PROPANE

ALTITUDE

A - 0'-10,000'

FIRING MODE

K - 2-STAGE (500 & 750)
N - 3-STAGE (1000)
L - 4-STAGE (1250,1500,

1750 & 2000)

LOCATION

C

INDOOR &

OUTDOOR

REVISION

2

SECOND

REV

HEAT EXCHANGER

B - GLASS-LINED CAST

IRON/COPPER/BRZ

TRIM (std. on PNCV)

C - GLASS-LINED CAST

IRON/COPPER

(std. on PNCH,

not avail. on PNCV)

N - GLASS-LINED CAST

IRON/CU-NICKEL

(not avail. on PNCV)

P - GLASS-LINED CAST

IRON / CU-NICKEL

BRZ TRIM

OPTIONS CODE

X - STANDARD

J - CSD-1, FM,

GAP, IL

PUMP OPTIONS

X - NO PUMP
H - PUMP-MTD, TACO

HARD WATER

PUMP (PNCV)

N - PUMP-MTD, TACO

NORM WATER

PUMP (PNCV, PNCH)

S - PUMP-MTD, TACO

SOFT WATER

PUMP (PNCV)

C - PUMP-MTD, B&G

HARD WATER

PUMP (PNCV)

B - PUMP-MTD, B&G

NORM WATER

PUMP (PNCV, PNCH)

D - PUMP-MTD, B&G

SOFT WATER

PUMP (PNCV)

HLW STAMP (PNCV only)

2 - GLASS-LINED CAST

IRON / COPPER / BRZ

TRIM
5 - GLASS-LINED CAST

IRON / CU-NICKEL,

BRZ TRIM