Page 13

Model and

Distance from Gas Meter or Last Stage Regulator

Gas Type

0-50 feet

0-15m

50-100 feet 15-31m

100-200 feet 31-61m

200-300 feet

61-91m

1200 natural

2"

5.1cm

2-1/2"

6.4cm

2-1/2"

6.4cm

3"

7.6cm

1200 propane

1-1/2"

3.8cm

2"

5.1cm

2"

5.1cm

2-1/2"

6.4cm

1600 natural

2-1/2"

6.4cm

2-1/2"

6.4cm

3"

7.6cm

3"

7.6cm

1600 propane

2"

5.1cm

2"

5.1cm

2-1/2"

6.4cm

2-1/2"

6.4cm

2000 natural

3"

7.6cm

3"

7.6cm

3"

7.6cm

3-1/2"

8.9cm

2000 propane

2-1/2"

6.4cm

2-1/2"

6.4cm

2-1/2"

6.4cm

3"

7.6cm

2400 natural

2-1/2"

6.4cm

3"

7.6cm

3"

7.6cm

3-1/2"

8.9cm

2400 propane

2"

5.1cm

2-1/2"

6.4cm

2-1/2"

6.4cm

3"

7.6cm

Notes:

1. These figures are based on 1/2" 0.12kPa water column pressure drop.

2. Check supply pressure and local code requirements before proceeding with work.

3. Pipe fittings must be considered when determining gas pipe sizing.

Table 6 - Gas Piping Sizes

At the time of removal of an existing boiler, the

following steps shall be followed with each appliance

remaining connected to the common venting system

placed in operation, while the other appliances

remaining connected to the common venting system are

not in operation.

1. Seal any unused openings in the common venting

system.

2. Visually inspect the venting system for proper

size and horizontal pitch and determine there is

no blockage or restriction, leakage, corrosion and

other deficiencies which could cause an unsafe

condition.

3. Insofar as it is practical, close all building doors

and windows and all doors between the space in

which the appliances remaining connected to the

common venting system are located and other

spaces of the building. Turn on clothes dryers

and any appliance not connected to the common

venting system. Turn on any exhaust fans, such

as range hoods and bathroom exhausts, so they

will operate at maximum speed. Do not operate a

summer exhaust fan. Close fireplace dampers.

4. Place in operation the appliance being inspected.

Follow the lighting instructions. Adjust thermostat

so appliance will operate continuously.

5. Test for spillage at the draft hood relief opening

after 5 minutes of main burner operation. Use

the flame of a match or candle, or smoke from a

cigarette, cigar or pipe.

6. After it has been determined that each appliance

remaining connected to the common venting

system properly vents when tested as outlined

above, return doors, windows, exhaust fans,

fireplace dampers and any other gas burning

appliance to their previous conditions of use.

7. Any improper operation of the common venting

system should be corrected so that the installation

conforms to the National Fuel Gas Code, ANSI

Z223.1/NFPA 54 and/or CSA B149.1, Installation

Codes. When resizing any portion of the common

venting system, the common venting system

should be resized to approach the minimum size

as determined using the appropriate tables

and guidelines in the National Fuel Gas Code,

ANSI Z223.1 NFPA 54 and/or CSA B149.1,

Installation Codes.

Section 3

GAS SuPPLy AND PIPING

3.1 Gas Supply and Piping

Gas piping should be supported by suitable

hangers or floor stands, not the appliance.

Review the following instructions before

proceeding with the installation.

1. Verify that the appliance is fitted for the proper

type of gas by checking the rating plate. LAARS

Heating Systems appliances are normally equipped

to operate at elevations up to 2000 feet (610m).

However, the appliance will function properly

without the use of high altitude modification at

elevations up to 10,000 feet (3050 m).

2. The maximum inlet gas pressure must not

exceed 13" W.C. (3.2kPa). The minimum

inlet natural gas pressure is 4" W.C. (1.0kPa)

and minimum inlet propane gas pressure is 6"

(1.5kPa).

3. Refer to Table 6, size supply.

4. Run gas supply line in accordance with all

applicable codes.

Note: If you have a boiler/water heater with

a normally open vent valve, install a vent line

from the vent valve to an outside location

as required by your installation code or IRI

requirement. Do not remove 3/4 inch pipe

plug from the vent valve if venting from the

normally open vent valve is not required by

your installation code.

5. Locate and install manual shutoff valves in

accordance with state and local requirements.

6. A sediment trap must be provided upstream of

the gas controls.