Vermont castings, majestic products: dvr33, General venting information–termination location – Vermont Casting DVR33 User Manual

Page 10

Advertising
background image

10

Vermont Castings, Majestic Products: DVR33

10004920

Canadian Installations

1

US Installations

2

A = Clearance above grade, veranda, porch,

12 in. (30 cm)

12 in. (30 cm)

deck or balcony

B = Clearance to window/door that may be opened 6 in. (15 cm) for appliances <10,000 Btuh 6 in. (15 cm) for appliances <10,000 Btuh

(3 kW); 12 in (30 cm) for appliances

(3 kW); 9 in. (23 cm) for appliances

>10,000 Btuh (3 kW) and <100,000 Btuh

>10,000 Btuh (3 kW) and <50,000 Btuh

(30 kW); 36 in. (91 cm) for appliances

(15 kW); 12 in. (30 cm) for appliances

>100,000 Btuh (30 kW)

>50,000 Btuh (15 kW)

C = Clearance to permanently closed window

12 in. (305 mm) recommended to

12 in. (305 mm) recommended to

prevent window condensation

prevent window condensation

D = Vertical clearance to ventilated soffit located

above the terminal within a horizontal distance 18 in. (458 mm)

18 in. (458 mm)

of 2 ft. (610 mm) from the center line of the
terminal

E = Clearance to unventilated soffit

12 in. (305 mm)

12 in. (305 mm)

F = Clearance to outside corner

(See next page.)

(See next page.)

G = Clearance to inside corner

(See next page.)

(See next page.)

H = Clearance to each inside of center line

3 ft. (91 cm) within a height of 15 ft. (4.57 m) 3 ft. (91 cm) within a height of 15 ft. (4.57 m)

extended above meter/regulator assembly

above the meter/regulator assembly

above the meter/regulator assembly

I = Clearance to service regulator vent outlet

3 ft. (91 cm)

3 ft. (91 cm)

J = Clearance to non-mechanical air supply

6 in. (15 cm) for appliances <10,000 Btuh 6 in. (15 cm) for appliances <10,000 Btuh

inlet to building or the combustion air inlet

(3 kW); 12 in. (30 cm) for appliances

(3 kW); 9 in. (23 cm) for appliances

to any other appliance

>10,000 Btuh (3 kW) and <100,000 Btuh

>10,000 Btuh (3 kW) and <50,000 Btuh

(30 kW); 36 in (91 cm) for appliances

(15 kW); 12 in. (30 cm) for appliances

>100,000 Btuh (30 kW)

>50,000 Btuh (15 kW)

K = Clearance to a mechanical air supply inlet

6 ft. (1.83 m)

3 ft. (91 cm) above if within 10 ft. (3.05 m)
horizontally

L = Clearance above paved sidewalk or a

7 ft. (2.13 m)†

7 ft. (2.13 m)†

paved driveway located on public property

M = Clearance under veranda, porch, deck or

12 in. (30 cm)‡

12 in. (30 cm)‡

balcony

N = Clearance above a roof shall extend a minimum of 24” (610 mm) above the highest point when it passes through the roof

surface, and any other obstruction within a horizontal distance of 18” (450 mm).

General Venting Information–Termination Location

1 In accordance with current CSA-B149 Installation Codes.
2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Codes.
† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single-family dwellings,

and which serves both dwellings.

‡ Only permitted if veranda/porch/deck is fully open on a of minimum two sides beneath the floor.
NOTES: • Local codes or regulations may require different clearances.

• The special venting system used on Vermont Castings, Majestic Products Direct Vent Fireplaces are certified

as part of the appliance, with clearances tested and approved by the listing agency.

V

V

V

V

V

V

V

X

X

X

D

E

B

B

B

C

B

M

B

A

J

K

F

L

VENT TERMINATION

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

H

I

Fixed

Closed

Fixed

Closed

Operable

Operable

Fixed

Closed

V

B

INSIDE

CORNER DETAIL

V

A

G

V

N

N

V

V

G

G

A

Fig. 11 Vent termination clearances

CFM145a