Vermont castings, majestic products: dvr33, Eb-1 electrical box – Vermont Casting DVR33 User Manual

Page 8

Advertising
background image

8

Vermont Castings, Majestic Products: DVR33

10004920

FP580

Fig. 9 EB-1 receptacle.

5. Connect black wire of the power supply line to the

brass screw (polarized) of the socket assembly.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable
with the clamp on the outside of the unit to prevent
strain on the connections.

9. The EB-1 electrical junction box is now ready to

supply power to the FK-12 or FK-24 fan kits, if so
fitted.

Outside

Electrical Box

Front of Unit

Inside

Front of Unit

Retaining Screw

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code

For USA installations, follow the local
codes and the national electrical code
ANSI/NFPA No. 70.

It is strongly suggested that EB-1
Electrical Junction Box wiring be carried
out by a licensed electrician.

Ensure that the power to the supply line
has been disconnected before
commencing this procedure.

The EB-1 electrical junction box has been supplied
standard with this model to allow for easy installation of
an optional fan kit.

To connect the EB-1 box to the house electrical supply
follow the steps below.

1. Unscrew the retaining screw from the EB-1 base

plate (Fig. 9), and remove the EB-1 assembly from
the fireplace.

2. Remove the front cover of the EB-1 box.
3 Remove the plug socket assembly from the EB-1 box.
4. Feed the supply line in from the outside through the

cable clamp (Fig. 9).

EB-1 Electrical Box

Advertising