Vermont Castings, Majestic Products: DVR33

10004920

Fig. 5 Adjustable drywall strip (nailing flanges).

C

A

B

Adjustable Drywall Strip

(Nailing Flange)

Screw

Drywall

Position

Depths

A

1/2” (13 mm)

B

5/8” (16 mm)

C

3/4” (19 mm)

FP1023

Adjustable

1/2”, 5/8” &

3/4” Spacing

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover the window frame assembly, any
vent, louvre assembly top or louvre assembly
bottom.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.

Final Finishing

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the
current ANSI Z223.1 and/or local codes having
jurisdiction.

In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370 m).

Inlet Minimum

5.5” w.c.

11” w.c.

Inlet Maximum

14” w.c.

14” w.c.

Manifold Pressure

3.5” w.c.

10” w.c.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

DVR33

CERTIFIED TO

ANSI Z21.88-2002 / CSA 2.33-2002

Vented Gas Fireplace Heaters

Gas Specifications

Max.

Min.

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

DVR33RN

Nat

Millivolt

20,000

14,000

DVR33RP

Prop

Millivolt

20,000

15,000

DVR33EN

Nat

24 V Hi/ Lo

20,000

14,000

DVR33EP

Prop

24 V Hi/ Lo

20,000

15,000

1. Choose the unit location.

2. Place the unit into position and secure it to the floor

with 1.5” (38 mm) screws, or nails. The holes to
secure the unit to floor are located just behind the
access door grille on the left and right side of the
unit.

3. Frame in the fireplace with a header across the top.

It is important to allow for the finished wall face
when setting the depth of the frame.

4. Attach the fireplace to the frame using the adjustable

frame drywall strips (located behind the access
door for shipping). Preset the depth to suit the
facing material of the wall. The strips are adjustable
to 1/2” (13 mm), 5/8” (16 mm), or 3/4” (19 mm).
(Fig. 5)

5. Screw through the slotted holes in the drywall strip

and into predrilled holes in fireplace side. Measure
from face of fireplace to the face of the drywall strip to
confirm the final depth.

Check fireplace to make sure it is
levelled and properly positioned.

Framing and Finishing

Advertising