High-Speed Microcontroller User’s Guide: DS80C390 Supplement

36 of 158

established by the P4CNT register. Note that the chip-enable range when using
A0-A15 is 32kB instead of the expected 64kB. This is to allow the use of more
common 32kB memory devices rather than 64kB devices.

Port 5 Pin Function

P5CNT.2-0

P5.7 P5.6 P5.5 P5.4

000

I/O I/O I/O I/O

100 I/O I/O I/O PCE0
101 I/O I/O PCE1

PCE0

110 I/O PCE2

PCE1

PCE0

111

PCE3

PCE2

PCE1

PCE0

The memory range addressable by each PCEx signal is a function of the total
number of address lines (A19-A16) established by the P4CNT register. Note that
the chip-enable range when using A0-A15 is 32 KB instead of the expected 64kB.
This is to allow the use of more common 32 KB memory devices rather than
64kB devices.

Port 5 Pin Function

P4CNT.5-3 PCE0

PCE1

PCE2

PCE3

000

0 – 32kB

32 – 64kB

64 – 96kB

96 – 128kB

100

0 – 128kB

128 – 256kB

256 – 384kB

384 – 512kB

101

0 – 256kB

256 – 512kB

512 – 768kB

768kB - 1MB

110

0 – 512kB

512 - 1MB

1 - 1.5MB

1.5 - 2MB

111

0 - 1MB

1 - 2M

2 - 3MB

3 - 4MB

CAN 0 CONTROL REGISTER (C0C)

7 6 5 4 3 2 1 0

SFR A3h

ERIE

STIE

PDE

CRST

AUTOB

ERCS

SWINT

RW-0 RW-0 RW-0 RW-0 RT-1 RW-0 RW-0 RW-1

R = Unrestricted Read, W = Unrestricted Write, T = Timed Access Write Only, -n = Value after Reset

ERIE
Bit 7

CAN 0 Error Interrupt Enable.
0 = CAN 0 Error Interrupt is disabled.
1 = Setting this bit while the C0IE bit (EIE.6) and Global Interrupt Enable bits
(IE.7) are set will generate an interrupt if the CAN 0 Bus Off (BUSOFF) or CAN
0 Error Count Exceeded bit (CECE) bits are set.

STIE
Bit 6

CAN 0 Status Interrupt Enable.
0 = CAN 0 Status Interrupt is disabled.
1 = If the C0IE bit (EIE.6) is set, an interrupt will be generated if the CAN 0
Transmit Status bit (TXS), Receive Status bit (RXS) or the Wake-Up Status bit
(WKS) is set. An interrupt will also be generated if the Status Error bits (ER2-0)
changes to a non-000b or non-111b state.

PDE
Bit 5

CAN 0 Power-Down Enable. Setting this bit places the CAN 0 module into its
lowest power mode. The module will enter power-down mode immediately upon
setting this bit, or following the completion of the current reception, transmission,
arbitration failure, or error condition on CAN 0. Software can poll the PDE bit to
ascertain whether the microcontroller has entered power-down mode (PDE=1) or
is waiting for a current CAN operation to complete (PDE=0) before entering