7.1. Time/Interval Setting

Set the start time and interval for battery check, external attenuator-connected speaker line check, and system
surveillance at power failure.

(1)

(2)

(1) Battery

Sets the start time and interval to check the conditions of the batteries selected in the Battery item of the
Surveillance Group Settings (see

p. 38

).

Time

Interval (displayed when "Time" item is not set to "Disable.")

(2) External ATT/AC-main failure status

Sets the start time and interval to check the conditions of the external attenuator-connected speaker lines
selected in the Speaker (Open/Short) item of the Surveillance Group Settings (see

p. 38

).

The Time/Interval set herein also allows all the surveillance items selected in the Surveillance Group
Settings to be performed in case of power failure.

Time

Interval (displayed when "Time" item is not set to "Disable.")

Notes

This function can be used only when all the versions of VM-3000VA firmware, VM-3000E firmware, and
VM-3000 Setting Software are 2.00 or later.

Since broadcast sound volume increases because attenuators are bypassed when the speaker line
surveillance is performed during broadcasts, it is recommended that the time and intervals be set for the
time zone in which no broadcast is scheduled.

Available Settings

Disable (default), 00:00 to 23:00 (in 1-hour steps)

Available Settings

4h (default), 24h

Available Settings

Disable (default), 00:00 to 23:00 (in 1-hour steps)

Available Settings

100 sec (default), 4h, 24h