* Changing the work clamp check

Use work clamp check ® having the size nearly the same as that of a buttonhole length.

By removing setscrew ©, a work clamp checks can be changed together with a work

clamp check holder as a set.

Work clamp checkAVork clamp

check holder set Part No.

Applicable knife width

GM344/10

l/4"~3/4"

GM347/10

l/4"-l"

GM348/10

l/4"~ 1—1/4"

18. REPLACING THE KNIFE^g^a^

When sharpening or replacing the knife, remove it as follows:

1) Loosen setscrew ©, and remove knife © together with the washer.

2) Attach the knife to the knife holder so that the higher end of the slanted knife blade

comes down 2 to 3mm above the surface of the throat plate when the knife if brought

down to the lowest position.

(NOTE); Do not forget to install the washer when retightening the setscrew.

23