Settings
0 to 19
Settings
Functions
Descriptions
0
Output frequency (Hz)
Max. frequency Pr.01-00 is regarded as 100%.
1
Frequency command
(Hz)
Max. frequency Pr.01-00 is regarded as 100%.
2
Motor speed (Hz)
600Hz is regarded as 100%
3
Output current (rms)
2.5 X rated current is regarded as 100%
4
Output voltage
2 X rated voltage is regarded as 100%
5
DC Bus Voltage
450V (900V)=100%
6 Power
factor
-1.000~1.000=100%
7
Power
Rated power is regarded as 100%
8
Output torque
Full-load torque is regarded as 100%
9 AVI
0~10V=0~100%
10 ACI
0~20mA=0~100%
11 AUI
-10~10V=0~100%
12
q-axis current
(2.5 X rated current) is regarded as 100%
13
q-axis feedback value
(2.5 X rated current) is regarded as 100%
14 d-axis
current
(2.5 X rated current) is regarded as 100%
15
d-axis feedback value
(2.5 X rated current) is regarded as 100%
16
q-axis voltage
250V (500V) =100%
17
d-axis voltage
250V (500V) =100%
18
Torque command
Rated torque is regarded as 100%