Pr.

Explanation

Settings

Factory

Setting

VF VFPG SVC FOCPG TQRPG

44: Reset initial reel diameter

○

○

○

○

○

45: Reset initial reel diameter 0

○

○

○

○

○

46: Reset initial reel diameter 1

○

○

○

○

○

47: Reset PID control integration of tension

○

○

○

○

○

48: Mechanical gear ratio switch

○

○

○

49: Reserved

50: Reserved

0: No function

11

○

○

○

○

○

02-11

Multi-function Output 1
RA, RB, RC(Relay1)

1: Operation indication

○

○

○

○

○

2: Operation speed attained

1

○

○

○

○

○

02-12

Multi-function Output 2
MRA, MRC (Relay2)

3: Desired frequency attained 1 (Pr.02-19)

○

○

○

○

○

4: Desired frequency attained 2 (Pr.02-21)

0

○

○

○

○

5: Zero speed (frequency command)

0

○

○

○

○

02-13

Multi-function Output 3
(MO1)

6: Zero speed with stop (frequency command)

○

○

○

○

7: Over torque (OT1) (Pr.06-06~06-08)

○

○

○

○

○

8: Over torque (OT2) (Pr.06-09~06-11)

○

○

○

○

○

9: Drive ready

0

○

○

○

○

○

02-14

Multi-function Output 4
(MO2)

10: User-defined Low-voltage Detection

○

○

○

○

○

11:

Malfunction

indication

○

○

○

○

○

12: Mechanical brake release (Pr.02-31)

○

○

○

○

○

02-35

Multi-function Output 5
(MO3)

13: Overheat

○

○

○

○

○

14: Software brake signal

○

○

○

○

○

15: PID feedback error

○

○

○

○

○

02-36

Multi-function Output 6
(MO4)

16: Slip error (oSL)

○

○

○

○

17: Terminal count value attained (Pr.02-16)

○

○

○

○

○

18: Preliminary count value attained (Pr.02-17)

○

○

○

○

○

02-37

Multi-function Output 7
(MO5)

19: Baseblock (B.B.) Indication

○

○

○

○

○

20: Warning output

○

○

○

○

○

21: Over voltage warning

○

○

○

○

○

02-38

Multi-function Output 8
(MO6)

22: Over-current stall prevention warning

○

○

○

○

○

23: Over-voltage stall prevention warning

○

○

○

24: Operation mode indication

○

○

○

○

○

02-39

Multi-function Output 9
(MO7)

25: Forward command

○

○

○

○

26: Reverse command

○

○

○

○

27: Output when current >= Pr.02-32

○

○

○

○

○

02-40

Multi-function Output
10 (MO8)

28: Output when current < Pr.02-32

○

○

○

○

○

29: Output when frequency >= Pr.02-33

○

○

○

○

○

30: Output when frequency < Pr.02-33

○

○

○

○

○

02-41

Multi-function Output
11 (MO9)

31: Y-connection for the motor coil

○

○

○

○

32:

Δ connection for the motor coil

○

○

○

○

33: Zero speed (actual output frequency)

○

○

○

○

02-42

Multi-function Output
12 (MOA)

34: Zero speed with Stop (actual output frequency)

○

○

○

○

35: Error output selection 1 (Pr.06-23)

○

○

○

○

○

36: Error output selection 2 (Pr.06-24)

○

○

○

○

○

37: Error output selection 3 (Pr.06-25)

○

○

○

○

○

38: Error output selection 4 (Pr.06-26)

○

○

○

○

○

39: Position attained (Pr.10-19)

○

40: Speed attained (including zero speed)

○

○

○

○

41: Multi-position attained

○

42: Crane function

○

○

○

○

43: Motor zero-speed output (Pr.02-43)

○

○

○

○

44: Max. reel diameter attained

○

○

○

○

○

45: Empty reel diameter attained

○

○

○

○

○

46: Broken belt detection

○

○

○

○

○

47: Break release at stop

○

○

○

○

48: Error PID feedback of tension

○

○

○

○

○

49: Reserved