Delta Electronics AC Motor Drive VFD-VE Series User Manual
Page 66

Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04
4-17
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQRPG
07-27
Source of Torque
Offset
0: Disable
1: Analog input (Pr.03-00)
2: Torque offset setting
3: Control by external terminal (by Pr.07-29 to Pr.07-
31)
0
○
○
○
07-28
Torque Offset Setting 0.0~100.0%
0.0
○
○
○
07-29
High Torque Offset
0.0~100.0%
30.0
○
○
○
07-30
Middle Torque Offset
0.0~100.0%
20.0
○
○
○
07-31
Low Torque Offset
0.0~100.0%
10.0
○
○
○
07-32
Forward Motor Torque
Limit
0~500% 200
○
○
07-33
Forward Regenerative
Torque Limit
0~500% 200
○
○
07-34
Reverse Motor Torque
Limit
0~500% 200
○
○
07-35
Reverse Regenerative
Torque Limit
0~500% 200
○
○
07-36
Emergency Stop (EF)
& Forced Stop
Selection
0: Coast stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: System Deceleration
6: Automatic Deceleration
0
○
○
○
○
○