Delta Electronics AC Motor Drive VFD-VE Series User Manual

Page 150

Advertising
background image

Chapter 4 Parameters|

Revision August 2008, 03VE, SW V2.04

4-101

Control Mode

Settings

VF

VFPG

SVC

FOCPG TQRPG

0: No fault

○

○

○

○

○

1: Over-current during acceleration (ocA)

○

○

○

○

○

2: Over-current during deceleration (ocd)

○

○

○

○

○

3: Over-current during constant speed (ocn)

○

○

○

○

○

4: Ground fault (GFF)

○

○

○

○

○

5: IGBT short-circuit (occ)

○

○

○

○

○

6: Over-curent at stop (ocS)

○

○

○

○

○

7: Over-voltage during acceleration (ovA)

○

○

○

○

○

8: Over-voltage during deceleration (ovd)

○

○

○

○

○

9: Over-voltage during constant speed (ovn)

○

○

○

○

○

10: Over-voltage at stop (ovS)

○

○

○

○

○

11: Low-voltage during acceleration (LvA)

○

○

○

○

○

12: Low-voltage during deceleration (Lvd)

○

○

○

○

○

13: Low-voltage during constant speed (Lvn)

○

○

○

○

○

14: Low-voltage at stop (LvS)

○

○

○

○

○

15: Phase loss (PHL)

○

○

○

○

○

16: IGBT heat sink over-heat (oH1)

○

○

○

○

○

17: Heat sink over-heat (oH2)(for 40HP above)

○

○

○

○

○

18: TH1 open loop error (tH1o)

○

○

○

○

○

19: TH2 open loop error (tH2o)

○

○

○

○

○

20: Fan error signal output

○

○

○

○

○

21: over-load (oL) (150% 1Min)

○

○

○

○

○

22: Motor 1 over-load (EoL1)

○

○

○

○

○

23: Motor 2 over-load (EoL2)

○

○

○

○

○

24: Motor PTC overheat (oH3)

○

○

○

○

○

25: Fuse error (FuSE)

○

○

○

○

○

26: over-torque 1 (ot1)

○

○

○

○

○

27: over-torque 1 (ot2)

○

○

○

○

○

28:

Reserved

29:

Reserved

30: Memory write-in error (cF1)

○

○

○

○

○

31: Memory read-out error (cF2)

○

○

○

○

○

32: Isum current detection error (cd0)

○

○

○

○

○

33: U-phase current detection error (cd1)

○

○

○

○

○

34: V-phase current detection error (cd2)

○

○

○

○

○

35: W-phase current detection error (cd3)

○

○

○

○

○

36: Clamp current detection error (Hd0)

○

○

○

○

○

37: Over-current detection error (Hd1)

○

○

○

○

○

38: Over-voltage detection error (Hd2)

○

○

○

○

○

39: Ground current detection error (Hd3)

○

○

○

○

○

40: Auto tuning error (AuE)

○

○

○

41: PID feedback loss (AFE)

○

○

○

○

○

42: PG feedback error (PGF1)

○

○

○

43: PG feedback loss (PGF2)

○

○

○

44: PG feedback stall (PGF3)

○

○

45: PG slip error (PGF4)

○

○

46: PG ref input error (PGr1)

○

○

○

○

○

47: PG ref loss (PGr2)

○

○

○

○

○

48: Analog current input loss (ACE)

○

○

○

○

○

49: External fault input (EF)

○

○

○

○

○

50: Emergency stop (EF1)

○

○

○

○

○

51: External Base Block (B.B.)

○

○

○

○

○

Advertising