Datalogic Scanning C-BOX 200 User Manual

Page 15

Advertising
background image

INSTALLATION

2

The following figure shows a multidrop layout with C-BOX 200 devices connected to
a Multiplexer:

MULTIPLEXER

C-BOX 200

# 0

C-BOX 200

# 1

C-BOX 200

# N

(up to 31)

SCANNER

CABLE SHIELD

RS485 REF

RTX485+

RTX485-

9

10

11

12

RTX485+

RTX485-

9

10

11

12

CABLE SHIELD

RS485 REF

CABLE SHIELD

RS485 REF

RTX485-

10

11

12

9

RTX485+

16

15

14

13

16

15

14

13 CABLE SHIELD

RS485 REF
RTX485+
RTX485-

CABLE SHIELD
RS485 REF
RTX485+
RTX485-

CABLE SHIELD
RS485 REF
RTX485+
RTX485-

SCANNER

SCANNER

EARTH GROUND

EARTH GROUND

EARTH GROUND

EARTH GROUND

(*)

max 1200 m

(*) If necessary enable the termination resistor only in the last device.

120 Ohm

Three wires + shield

Figure 6 - Multiplexer connection

7