Rs485 bus termination, Om4000 jumper settings – Datalogic Scanning C-BOX 200 User Manual

Page 20

Advertising
background image

C-BOX 200

2

2.4.5 RS485

Bus

Termination

ON

OFF


Figure 12 - Termination Resistance Switch


This switch enables or disables the insertion of the bus termination resistor for RS485
Half Duplex Multidrop applications.

CAUTION

In Multiplexer applications the termination resistor must be enabled
ONLY on the last device of the chain, the farthest away from the
Multiplexer (assuming the Multiplexer is the first device of the
chain). On all the other devices this resistor MUST NOT be enabled
(OFF position).

NOTE

For all RS485 connections, in case of electrically noisy environments:
C-BOX 200 should be connected to a good earth ground (pin 7 or 8),
RS485 CABLE SHIELD should be connected to pin 7 or 8, the scanner
chassis should be connected to EARTH GROUND through the jumper,
see Figure 10.



2.4.6

OM4000 Jumper Settings

J1

J2

Figure 13 - OM4000 Jumpers


The jumpers allow connection to the EXT TRIG signals on separate spring clamp
terminals for applications which use the OM4000 Oscillating Mirror in Trigger Mode.

12