INSTALLATION

2

2.7.1 GET/SEND

Buttons


The C-BOX 200 has two internal function buttons (GET, SEND).

C-BOX 200

GET SEND

Figure 15 – Internal Function Buttons



The procedure to enable the GET/SEND function is the following:

1. Press both the GET and SEND buttons at the same time for at least one second;

the warning LED will turn ON.

2. Release the buttons.

3. Press the left button corresponding to the GET function or the right button

corresponding to the SEND function.

GET

–

(left button): the C-BOX 200 reads the current scanner configuration
and permanently copies it in its own memory support (EEPROM). The
C-BOX 200 preserves this configuration also when switched off.

SEND

-

(right button): the C-BOX 200 sends the configuration previously stored
in its own permanent memory support to the scanner’s EEPROM.


NOTE

Once the buttons are released in step 1, a ten-second timeout starts.
If no button is pressed within this time (no function is selected), the
procedure will be cancelled.
The C-Box 200 warning LED will turn OFF at the end of each
procedure.

15