INSTALLATION

2

The C-BOX 200 spring clamp connector pinouts are indicated in the following table.

Refer to the scanner Installation Manual for details.

Pin Name
1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

*9, 13

RS485 CABLE SHIELD

*10, 14

RS485 REF

*11, 15

RTX485+

*12, 16

RTX485-

20, 33, 34, 40

Reserved

21 OUT1+
23 OUT2+
27 EXT

TRIG+

28 EXT

TRIG-

35 TXA
37 RXA
39 SGND

DS2100A
DS2400A

DS4600A

22 OUT

REF

OUT1-

24 OUT

REF

OUT2-

25, 26

NC

Reserved

29 NC

IN1+

30 NC

IN1-

31 NC

IN2+

32 NC

IN2-

36 RTSA

GND

38 CTSA

SGND

AUX

•

The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate network
connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the
network bus can enter and exit the C-Box 200 from different spring clamps but be physically connected
together.

NOTE

Pin 7 or 8 should be connected to the earth ground.

Pin 17, 18 and 19 are not present in the C-BOX 200 model.