System wiring – Datalogic Scanning C-BOX 200 User Manual

Page 16

Advertising
background image

C-BOX 200

2

2.4.1 System

Wiring


The connection and wiring procedure for C-BOX 200 is described as follows:

1)

Open the C-BOX 200 as described in paragraph 2.2.

2)

Verify that the C-BOX 200 power switch is off (see Figure 8).

3)

Unscrew the compression connectors and pass all the system cables
through them into the C-BOX 200 housing.

4)

To connect the power and input/output signals:

•

Prepare the individual wires of the system cables by stripping the
insulation back approximately 1 cm.

•

Using a device such as a screwdriver, push down on the lever directly
next to the clamp (see Figure 7).

•

Insert the wire into the clamp and release the lever.



The wire will now be held in the spring clamp.

Figure 7 - System Cable Connections


The wiring used can be solid or stranded but must meet the following specifications.

All positions:

24 - 16 AWG

0.2 - 1.5 mm²

8

Advertising