7 calibration, 1 before you proceed, 2 vr assignment – ADLINK PCI-9810 User Manual

Page 75: Before you proceed, Vr assignment, Table 7-1: functions of vrs, 7calibration

Advertising
background image

Calibration

63

7

Calibration

In data acquisition, you must calibrate your measurement devices
to maintain accuracy. You can calibrate the analog input and
analog output channels using your operating environment to
optimize accuracy. This chapter describes the calibration process
for the PCI-9812/9810 card.

7.1

Before You Proceed

You need the following equipment for the calibration process:

X

Calibration utility. This application guides you through the
calibration process and is available from the card package.

X

Voltage calibrator or a stable and noise-free DC voltage
generator.

7.2

VR Assignment

There are eight variable resistors (VR) on the PCI-9812/9810 card
that allows you to make accurate adjustments to the A/D
channels. The function of each VR is specified below.

VR1

A/D channel 0 offset adjustment

VR2

A/D channel 1 offset adjustment

VR3

A/D channel 2 offset adjustment

VR4

A/D channel 3 offset adjustment

VR5

A/D channel 0 full scale adjustment

VR6

A/D channel 1 full scale adjustment

VR7

A/D channel 2 full scale adjustment

VR8

A/D channel 3 full scale adjustment

Table 7-1: Functions of VRs