8 power, 9 mechanical and environmental, 10 operating systems support – ADLINK ETX-BT User Manual

Page 12: Operating systems support

Advertising
background image

Page 12

2.8 Power

X

Standard Input: ATX = 5V±5% / 5Vsb ±5% or AT = 5V±5%

X

Management: ACPI 4.0 compliant, Smart Battery support

X

Power States: C0, C1, C1E, C4, C6; S0, S3, S4, S5 (Wake on USB S3/S4,WOL S3/S4/S5)

X

ECO mode: supports deep S5 (ECO mode) for power saving

2.9 Mechanical and Environmental

X

Form Factor : ETX Rev 3.02

X

Dimension: 114 mm x 95 mm

X

Standard Operating Temperature: 0°C to +60°C

X

Screened Extreme Rugged™ Operating Temperature: -40°C to +85°C (optional)

X

Humidity: 5-90% RH operating, non-condensing

5-95% RH storage (operating with conformal coating)

X

Shock and Vibration:

IEC 60068-2-64 and IEC-60068-2-27

MIL-STD-202F,

Method

213B, Table 213-I, Condition A and

Method 214A, Table 214-I, Condition D

X

HALT Tested: Thermal Stress, Vibration Stress, Thermal Shock and Combined Test

X

MTBF: MIL-HDBK-217 FN2 models; Environment: GB, GC - Ground Benign, Controlled

Temperature:

85°C:

MTBF=79,548

hrs

Temperature: 40°C : MTBF=278,025 hrs

2.10 Operating Systems Support

X

Standard OS Support: Windows 7 & 8.1 32/64-bit, Linux 32/64-bit

X

Extended Support (BSP): WES7/8 32-bit, WEC7/8, Linux, VxWorks, QNX