Power specifications, Figure 2-9, E6xxt peak in-rush current and duration – ADLINK CoreModule 720 User Manual

Page 22: Table 2-5, Power supply requirements

Advertising
background image

Chapter 2

Product Overview

16

Reference Manual

CoreModule 720

Power Specifications

Table 2-5

provides the current measurements for the CoreModule 720.

Operating configurations:

In-rush operating configuration includes CRT monitor, 2GB memory, 8GB SSD, and power.

Idle operating configuration includes In-rush configuration as well as one SATA hard drive, USB mouse
and keyboard.

BIT (Burn-In-Test) operating configuration includes Idle configuration as well as four USB loop backs,
four serial ports with loop backs, and one Ethernet connection.

Figure 2-9. E6XXT Peak In-Rush Current and Duration

Table 2-5. Power Supply Requirements

Parameter

600MHz E620T
Characteristics

1.3GHz E660T
Characteristics

1.6GHz E680T
Characteristics

Input Type

Regulated DC voltages Regulated DC voltages Regulated DC voltages

In-rush Peak Current and
Duration

See

Figure 2-9

See

Figure 2-9

See

Figure 2-9

Typical Idle Current

1.67A (8.34W)

1.69A (8.43W)

1.67A (8.33W)

BIT Current

2.72A (13.61W)

2.85A (14.25W)

2.97A (14.85W)

Advertising