Thermal/cooling requirements, Figure 2-10. stack heights of cooling assemblies, Table 2-7 – ADLINK CoreModule 720 User Manual

Page 24: Adlink optional cooling solutions

Advertising
background image

Chapter 2

Product Overview

18

Reference Manual

CoreModule 720

Thermal/Cooling Requirements

The CPU is the primary source of heat on the board. The CoreModule 720 is designed to operate at the
maximum speed of the CPU and requires a cooling solution (available option). See

Table 2-7

for optional

cooling solution temperature qualifications.

Figure 2-10

depicts height measurements of the optional

cooling assemblies.

Figure 2-10. Stack Heights of Cooling Assemblies

Table 2-7. ADLINK Optional Cooling Solutions

Cooling Solution

Description

Passive Heatsink - Copper
(without fan)

Qualified to maintain optimal performance between -40°C and +85°C.
(Note: The E680T CPU is qualified only for -20°C to +70°C with a
copper heatsink.)

Passive Heatsink - Aluminum
(without fan)

Qualified to maintain optimal performance between -20°C and +70°C.
(Note: The E680T CPU is not qualified to use an aluminum heatsink.)

Active Heatsink
(with fan)

Qualified to maintain optimal performance between -40°C and +85°C.
(Note: The E680T CPU requires an active heatsink for temperatures
between +70°C and +85°C.)

NOTE

All heights are given in inches. Copper and aluminum passive cooling
assemblies share the same height measurements.

0.39

0.44

0.20

0.09

CM720_Cooling_Assy_hts_b

0.09

1.18

2.66

0.98

0.32

2.46

Active Heatsink

CoreModule 720

Fan

1.48

0.39

0.44

Passive Heatsink

CoreModule 720

Advertising