5 cnmoi, 6 cnmoe, Cnmoi – configuration monitor initiate – Dialogic SS7G2X User Manual

Page 51: Cnmoe – configuration monitor end, Cnmoi, Configuration monitor initiate, Cnmoe, Configuration monitor end

Advertising
background image

51

Dialogic

®

SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.5.5

CNMOI – Configuration Monitor Initiate

Synopsis

This command initiates the monitoring of an object on the Signaling Gateway. An object is currently a

C7LINK

.

For signaling, the

STS

monitors information sent from the

EQU

of the signaling link and the

RTS

monitors

information received by the signaling link.

Syntax

CNMOI:

C7LINK

=,

STS

=,

RTS

=;

Prerequisites

•

If specified, the

C7LINK

has already been initiated and must have a

TS

and

EQU

.

•

The

PCM

on which

STS

exists must have already been initiated and STS must be within the correct range

for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).

•

The

PCM

on which

RTS

exists must have already been initiated and RTS must be within the correct range

for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).

•

STS

is not already assigned elsewhere on the system for output.

•

RTS

is not already assigned elsewhere on the system for output.

•

A signaling link can only be monitored once.

Attributes

CONFIG

Examples

CNMOI:

C7LINK

=1,

STS

=3-3-15,

RTS

=5-3-16;

6.5.6

CNMOE – Configuration Monitor End

Synopsis

This command ends the monitoring of an object. An object is currently only an signaling link.

Syntax

CNMOE:

C7LINK

=;

Prerequisites

•

The

C7LINK

is being monitored.

Attributes

CONFIG

Examples

CNMOE:

C7LINK

=1;