CNMOP – Configuration Monitor Print

Synopsis

This command is used to obtain a print out of the objects being monitored. An object is currently only a
signaling link.

For signaling, the

STS

monitors information sent from the

EQU

of the signaling link and the

RTS

monitors

information received by the signaling link.

Syntax

CNMOP;

Prerequisites

None

Attributes

None

Examples

CNMOP;

Output Format

Monitoring Configuration
C7LINK STS RTS
1 3-3-1 3-3-2
3 3-3-3 3-3-4
EXECUTED

6.5.8

CNPCI – Configuration PCM Initiate

Synopsis

This command configures a PCM (

PCM

) for T1 or E1 operation (

PCMTYPE

) on a board such that it is available

for signaling or voice. The command optionally configures the PCM to be used as a potential synchronization
source for the system (

SYNCPRI

). The command also allows the frame format (FF) and line code (LC) to be

configured. See

Section 7.1.2, “Boards and PCMs” on page 136

for a more detailed description of PCM

configuration.

Syntax

CNPCI:

PCM

=,

PCMTYPE

=,[

SYNCPRI

=,][

FF

=,][

LC

=,][IDLE=][BM=][

BUILDOUT

=,];

Prerequisites

•

The board on which the

PCM

exists has been initiated.

•

The

PCM

has not already been initiated.

•

For a

PCMTYPE

of E1, the

LC

can be set to HDB3 and the

FF

can be set to G704, CRC4, CRC4C or

CRC4G706.

•

For a

PCMTYPE

of T1, the

LC

can be set to AMI or B8ZS and the

FF

can be set to SF, ESF or CRC6.

•

An

FF

of CRC4G706 can only be set on a board type of SS7HDP.

•

The

BUILDOUT

parameter can only have a value of 0 for E1 and a value of 1 for T1s on boards of a type

other than SS7HDP.

Attributes

CONFIG

Examples

CNPCI:

PCM

=1-1,

PCMTYPE

=E1,

SYNCPRI

=1;