9 cnpcc, 10 cnpce, Cnpcc – configuration pcm change – Dialogic SS7G2X User Manual

Page 53: 10 cnpce – configuration pcm end, Cnpcc, Configuration pcm change, Cnpce, Configuration pcm end

Advertising
background image

53

Dialogic

®

SS7G2x Signaling Server SGW Mode User Manual Issue 4

6.5.9

CNPCC – Configuration PCM Change

Synopsis

This command allows changes to the configuration of a

PCM

.

Syntax

CNPCC:

PCM

=,{[

PCMTYPE

=,]|[

SYNCPRI

=,][

FF

=,][

LC

=,][IDLE=][BM=][

BUILDOUT

=,]};

Prerequisites

•

The

PCM

has already been initiated.

•

For a

PCMTYPE

of E1, the

LC

can be set to HDB3 and the

FF

can be set to G704, CRC4, CRC4C or

CRC4G706.

•

For a

PCMTYPE

of T1, the

LC

can be set to AMI or B8ZS and the

FF

can be set to SF, ESF or CRC6.

•

An

FF

of CRC4G706 can only be set on a board type of SS7HDP.

•

The

BUILDOUT

parameter can only have a value of 0 for E1 and a value of 1 for T1s on boards of a type

other than SS7HDP.

Attributes

CONFIG

Examples

CNPCC:

PCM

=1-1,

SYNCPRI

=3;

6.5.10

CNPCE – Configuration PCM End

Synopsis

This command ends the configuration of a

PCM

such that it is unavailable for voice or signaling.

Syntax

CNPCE:

PCM

=;

Prerequisites

•

No timeslot on the

PCM

has been assigned to voice, signaling monitoring or cross connections.

•

The board on which the

PCM

exists has been blocked.

Attributes

CONFIG

Examples

CNPCE:

PCM

=1-1;

Advertising