Using DCS120

Step information for the MMC120 is generally programmed using DCS120, but you can modify the Step table
directly with the P/C by using Command Type E and Extended E (see pages 63 and 64).

MMC120 0.99

DELTA Computer Systems, Inc.

19990709

0

1

2

3

4

5

6

7

8

9

MODE

00000

00001

08081

00080

00000

00000

00000

00000

00000

00000

ACCEL

0

100

100

0

0

0

0

0

0

0

DECEL

0

20

100

0

0

0

0

0

0

0

SPEED

0

5000

1000

0

0

0

0

0

0

0

POSITION

00000

20000

2000

0

0

0

0

0

0

0

COMMAND

G

G

G

LINK TYPE

L

0A0

LINK VALUE

0

10000

0

0

0

0

0

0

0

0

LINK NEXT

0

2

3

0

0

0

0

0

0

0

LINK TYPES

LINK VALUES

LINK NEXT

0

End of Chain

N/A

N/A

B

Status Bits

bits in hex

next Step number

D

Delay 0

milliseconds

next Step number

L

Limit Switch

position units

next Step number

S

Speed

position units/sec

next Step number

E

Enhanced

parameter dependent

next Step number

Accessing the DCS120 Step Editor screen

To go to the Step Editor screen from the main DCS120 screen, press Ctrl-S. To return to the main screen,
press Esc.

Step Editor Commands

To cut and paste regions of the table, hold down the Shift key and move around with the cursor keys to select
the desired region. After you select it, you can cut it with Ctrl-X or copy it with Ctrl-C and paste it with Ctrl-V.

Ctrl-G will 'go' to the next Step in the sequence. You can use Ctrl-G to step through a sequence and confirm it
operates as expected. If you enter an 'e' in the link type field, the Enhanced Event Editor will start. This editor
will assemble the needed link type value based on your selections in this editor.

Ctrl-Z will set all values in the table to zero.