Delta MMC120 User Manual

Page 102

Advertising
background image

Appendix B: Event Control

MMC120 Linear Motion Control Module

102

Delta Computer Systems, Inc 360/254-8688

Reading Step files from disk and module

To read a Step file from disk to DCS120, press Ctrl-R. A list of available step files will be displayed; enter the
desired file name and press Enter (but do not enter the .ST1 extension). To read the Step file from the
MMC120 to DCS120, press Alt-R.

Sending Step files to disk, module, and Flash memory

To save a Step file from DCS120 to disk using the current file name, press Ctrl-S; to save it with a new file
name, enter "s filename" on the command line (do not enter the '.BD1' extension; DCS120 automatically adds
the correct extension). To send a Step file from DCS120 to the MMC120, press Alt-S. To save the Step file
currently in the MMC120 to FLASH memory, enter '2' in the Position field, then press Alt-U. The 'U'
command uses the Acknowledge bit (9) of the Status word to report the result of the update. If the FLASH
updates successfully, bit 9 of axis 1 is set; if the update was unsuccessful, bit 9 of axis 2 is set.

Step Table

Send/Receive

Commands

Disk

DCS120

MMC120

FLASH

Alt-R

x <---------------x

Alt-S

x -------------->x

Ctrl-R

x ------> x

Ctrl-S

x <------ x

Alt-U(2)

x ------------> x

Advertising