EXFO FTB-8500 Series for FTB-500 User Manual

Page 115

Advertising
background image

Creating and Starting a Test Case

Ethernet and Fibre Channel Application

101

Ethernet Frame Analyzer Test Case

To create a Frame Analyzer test case:
1.
Test configuration:

1a. Select Ethernet 10/100/1000 or

Ethernet 10G as the Interface Type.
Interface Type is not available with
FTB-8510G.

1b. For FTB-8510B: Select the Topology test

type: Single Port or Dual Ports.

1c. Select Frame Analyzer as the Application Type.

1d. Select the IPTV (Internet Protocol Television) check box to give

access to the IPTV testing capability. IPTV is a software option
available on FTB-8510B only and needs to be enabled to be
available (refer to Software Options on page 378). IPTV testing is
always performed on Port 1. PBB-TE and MPLS testing
capabilities are not available when the IPTV check box is selected
and vice versa. The IPTV check box is cleared by default.

1e. Select the Through Mode check box to enable Ethernet

bi-directional in-line traffic monitoring between two end points in
a non-intrusive manner using both FTB-8510B test ports. Stream,
alarm and error generation as well as Ping and Trace Route
capabilities are not supported. Through Mode is a software
option available on FTB-8510B only and needs to be enabled to be
available (refer to Software Options on page 378). Through Mode
testing is only available in Dual Ports topology. The Through
Mode
check box is cleared by default.

1f. Press Next.

Advertising
This manual is related to the following products: