Configuration – EXFO FTB-8500 Series for FTB-500 User Manual

Page 322

Advertising
background image

RFC 2544 Tabs

308

FTB-8500 Series and FTB-8120NGE/8130NGE

Back-to-Back

Configuration

Max. time worth of frame (MM:SS): Choices are 1 to 5 seconds. The
default setting is 1 second (00:01).

Accuracy (Frames): Enter the Accuracy measurement value in frames.
Choices are 1 to 50 frames. The default setting is 1.

Nb of Acceptable Errors: Select the number of acceptable errors for
the test. Choices are 0 to 10 errors. The default setting is 0 error.

Nb of Trials to Average: Select the number of times the throughput
test will be generated. Choices are 1 to 100 trials. The default setting is
1 trial.

Nb of Burst: Select the number of burst that will be generated. Choices
are 1 to 10 Bursts. The default setting is 1 Burst.

Minimum Test Time (Seconds): Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.