EXFO FTB-8500 Series for FTB-500 User Manual

Page 99

Advertising
background image

Creating and Starting a Test Case

Ethernet and Fibre Channel Application

85

Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases

1e. Press Scan Subnet to scan the subnet to find remote compatible

modules (FTB-8510B, FTB-8510G, FTB-8525/FTB-8535,
FTB-8120NGE/FTB-8130NGE, AXS-850 Series (RFC 2544 only),
FTB-860 Series, FTB-810/880 Series, or RTU-310/RTU-310G). The
subnet scan will work only when both remote and local modules
are on the same subnet. Only modules running the same test
(RFC 2544 or EtherSAM) and having the Remote Dual Test Set
mode enabled will be listed.

The detected remote compatible module are listed with their IP
Address
, Remote ID, and Status information.

1f. Select a detected module from the list by pressing on it, and press

Select. The connection is possible with a module having its status
Not Connected or Busy. A confirmation is required when
selecting a remote module having its status Busy since the
remote unit may be connected to another module.

1g. Press the Connect button to establish the connection with the

remote module. The connection is possible with a module having
its status Not Connected or Busy. A confirmation is required
when selecting a remote module having its status Busy since the
remote unit may be connected to another module.

Disconnect allows to disconnect from the remote module.

1h. Press Finish to complete the test setup on this local module. For

RFC 2544, the RFC 2544’s Global tab is automatically displayed.

Status

Description

Not Connected The remote module is not connected to another module.

Busy

The remote module is connected to another module.

Connected

The remote module is connected to the current module.

Remote IP not
found

The local module didn’t receive any reply from the

selected remote module IP address.

Advertising
This manual is related to the following products: