Creating and Starting a Test Case

Ethernet and Fibre Channel Application

79

Ethernet EtherSAM (Y.1564) and RFC 2544 Dual Test Set Test Cases

To create an EtherSAM (Y.1564) or RFC 2544 Dual Test Set test

case, first create the test on the remote module as follow:
1.
Test configuration:

1a. Select

Ethernet 10/100/1000 or
Ethernet 10G as the
Interface Type. Interface
Type
is not available with
FTB-8510G.

1b. Select Single Port as the

Topology. Topology is only
available with FTB-8510B.

1c. Select EtherSAM (Y.1564)

or RFC 2544 as the Application Type.

1d. Select the Dual Test Set check box to enable the control of a

remote compatible module (FTB-8510B, FTB-8510G,
FTB-8525/FTB-8535, FTB-8120NGE/FTB-8130NGE, or
RTU-310/RTU-310G). For FTB-8510B, Dual Test Set is only
available in Single Port Topology. This setting is not selected by
default.

1e. Select the Remote test Mode.

1f. Type an ID for this remote unit. Up to 16 characters are allowed.

1g. For FTB-8120NGE and FTB-8130NGE, select the latency

measurement mode; Round-Trip or One-Way. For more
information, refer to Latency Measurement on page 301 for
RFC-2544, or Latency Measurement on page 327 for EtherSAM.

1h. Press Next.